Activated Charcoal Filter (Recirculation Version)
Can be washed in the dishwasher. It must be washed when button “C” lights up or at least
once every 4 months, or more frequently if use is particularly intense. Guaranteed to operate
after washing for up to a maximum of 5 times before requiring replacement. The Alarm signal,
if it has been activated, only appears when the Suction motor is turned on.
Activating the alarm signal
In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
Turn the Lights and the Suction Motor off.
Press and hold button B for 2 seconds:
• Symbol C” flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• Symbol C” flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
Turn the Lights and the Suction Motor off.
• Press button B (see paragraph on Use).
Changing the Filter
Remove the comfort panel.
Remove the Metal grease filters.
Remove the metal filter stops from the grease
filter and clean the saturated activated
charcoal odour filter.
• Replace the clean activated charcoal filter,
hooking it back up to the grease filter using
the metal filter stops.
Replace the Metal grease filters.
Close the comfort panel.
Lighting unit
Warning: This appliance is fitted with a white LED lamp classed as 1M
according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maxi-
mum optical power emitted @439nm: 7µW. Do not look directly at the
light through optical devices (binoculars, magnifying glasses…).
For replacement contact technical support. ("To purchase contact tech-
nical support")